You are here: Home / Solution

What Problems Can Our Fuel Dispenser Parts Solve?

  •  

    The standard tank truck on the market is expensive, and many small oil operators buy large costs and invest, most of them use van or minibus to refit themselves. If you buy standard fuel dispenser , most of this machine without oil pump to be configured, installation is troublesome and take up space.
    Constant and company after many tests, 12V/24V DC pump car with small fuel dispenser was finally perfect birth, to the majority of small oil operators brought good news. This kind of car fuel dispenser with pump is fully functional and affordable, with 12V or 24V battery power supply, small volume does not occupy space, easy installation is the essential product of oil business.


    Technical parameters of fuel dispenser:

    Item No.

    Specification

       Rate Of Flow

      5~50 L/MIN

      Accuracy of measurement

      Maximum allowable error is not more than ± 0.3%, repeatability error is not more than ±0.15%;
      The minimum measurement error is not more than ± 0.5%, repeatability error is not more than ±0.25%;

      Dryness

      Less than 80dB(A sound level);

      Display digit

      1) Litre: 6 or 8 bits; 2) Amount: 6 or 8; 3) Unit price: 4 or 6 seats;

      Volume counting range

      0.00~999999999.99L

      Amount count range

      0.00~999999999.99$

      Unit price setting range

      0.00~99.99$/L

      Solenoid valve closed in advance

      00.99L;

      Using the environment

      1) Temperature -45℃~ +55℃; 2) Humidity 30%~90%;

      Inlet pressure
      Outlet pressure

      1) Suction inlet pressure 54kpa;
      2) The outlet pressure shall not exceed 0.3mpa;

      Explosion-proof grade

      Ex dib II AT39

      The power supply

      1) Voltage :DC12V or DC24V/AC220V 2) Frequency: 50Hz or 60Hz;
     
    12V24V mobile fuel dispenser
     
    12V24V mobile fuel dispenser1
     
    12V24V mobile fuel dispenser3
     
     
  •  
    Introduction to oil and gas recovery system

    Oil and gas recovery can be divided into two stages: primary and secondary oil and gas recovery. When unloading oil from the tank truck to the tank, the oil and gas in the tank are recovered to the tank car, which is generally called primary oil and gas recovery. When the tanker refuels the car, the oil and gas from the car tank is recovered to the oil storage tank, which is called secondary oil and gas recovery.
    Gasoline is a very volatile substance. When the tank truck dumps oil to the tank and the car refuels, the oil and gas in the tank and the empty tank of the car will be discharged. The agitation of the gasoline in the tank and the tank will produce a lot of oil and gas, and the natural volatilization of the gasoline in the tank will also produce a lot of oil and gas. If the gas is not recovered and treated, it will permeate the gas station environment and eventually escape to the atmosphere. Being in the environment of oil and gas for a long time will cause harm to the body, the discharge of oil and gas into the atmosphere will cause environmental pollution, and the pervading of oil and gas in the environment of gas stations is still a potential safety hazard.
    Oumite two-stage oil and gas recovery system will recover oil and gas into underground storage tanks, oil and gas emission treatment device will convert oil and gas into liquid gasoline, and control the emission in accordance with environmental standards, not only protect the environment and eliminate adverse safety and health factors, but also can save a lot of energy.


    Schematic diagram of Oumite secondary oil and gas recovery and treatment system.
    Static grounding alarm
  •  

    Static electricity prevention is very important in the loading, unloading and transportation of chemical oil. A good static electricity grounding alarm can effectively prevent and eliminate static electricity and prevent safety accidents caused by static electricity.Henghe Jiahua technology company according to market demand, research and development team after long-term hard work, a new generation of static telegraph grounding alarm came into being. The new static alarm has obtained high grade explosion-proof certification, which is suitable for a wider range of anti-static work occasions; The new generation of electrostatic grounding alarm adopts dual power lithium battery, the power is strong and durable, not to worry about changing the battery.

     
    Introduction to oil and gas recovery system
     

    Static grounding alarm: used in gas station, oil depot, tank car, chemical plant and other places prone to static electricity, static electricity can be exported to prevent accidents caused by static electricity overvalue.
    1. Pass the explosion-proof grade Exib II CT4 test and obtain the explosion-proof certificate;
    2. adopt advanced SCM control technology, stable and reliable performance;
    3. grounding circuit voltage automatic monitoring, static voltage automatic alarm;
    4. no switch operation 24 hours automatic duty;
    5. quick response ability, can make alarm response within 1 second;
    6. ultra-low power consumption design, durable power supply of lithium battery;
    7. easy to install, stable performance, after 72 hours of aging and a number of strict inspection;
    8. The grounding wire is 3 meters long, and the electric clamp is 5 meters long;
    9. size:3 50*270*150; Weight: 3.5 kg.

     

    Static grounding alarm parameters:
    Explosion-proof grade: Exib II CT4
    Working pressure: DC3V
    Working current: dynamic ≤ 1mA Static 60uA
    Electrostatic alarm voltage: ≥250V
    Alarm volume: ≥ 90dB
    Operating temperature: -10~50℃
    Ground resistance: < 60 OU

     

  Tel: +86-13511700640
  E-mail: parts@chinahenghe.com
  Add: Sanjiang Pier Oubei Yongjia Wenzhou Zhejiang China

QUICK LINKS

PRODUCT

CONTACT US

Contact Us
Copyright © 2022 Zhejiang Bolai Fluid Equipment Manufacturing Co., Ltd.     All Rights Reserved.   Sitemap | Support By Leadong   浙ICP备2022005143号-1